Diesel generator set - DOOSAN BC-H241D-60 (193 kW / 241 kVA)
BOCHI POWER Doosan gensets use Doosan SP and DP family engines with a robust architecture and low specific fuel consumption. Integrated and tested by BOCHI POWER.
| Model | BC-H241D-60 |
| Standby power | 241 kVA / 193 kW |
| Prime power | 219 kVA / 175 kW |
| Engine | P086TI |
| Frequency | 60 Hz |
| Voltage | Multi-voltage 110/208 - 277/480 V |
| Phases | Three-phase, four-wire |
| Dimensions (mm) | 2650 x 1000 x 1800 |
| Type | Open set |
Built, integrated and tested by BOCHI POWER.
Overview
The Diesel Generator Set - DOOSAN BC-H241D-60 (193 kW / 241 kVA) is a 241 kVA / 193 kW standby diesel generator set, built around a P086TI engine and open type configuration. It delivers 60 Hz, three-phase four-wire, at 110/208 V – 277/480 V.
At this rating the set backs up a whole building or production line: process plants, industrial units and commercial centres where an outage is not an inconvenience but a production stop with a direct cost. BCP’s Doosan range spans 8 to 1100 kVA with Doosan power, intended for standby duty and for extended running depending on how the fuel and cooling system is specified.
Typical applications
- Industrial units and process plants
- Logistics and distribution centres
- Hospitals and corporate buildings
- Food and beverage plants
- Infrastructure and civil works
Standby and prime ratings
The standby rating (241 kVA / 193 kW) is what the set delivers during a grid outage, for a limited number of hours a year and without sustained overload. The prime rating (PRP) allows continuous duty with varying load. Sizing starts from the real load in kW, corrected by power factor, with headroom left for motor starting.
Frequently asked questions
What is the difference between standby and prime?
Standby is the power available in an emergency, limited to a set number of hours a year; prime is what the set can sustain continuously with varying load. A set sized for standby should not be used as prime generation without re-checking the duty.
What voltage and connection does the BC-H241D-60 deliver?
It is offered at 110/208 V – 277/480 V, three-phase four-wire, 60 Hz. Final nameplate voltage is fixed at order stage according to the site network and the transfer arrangement.
Is one set of this size better than two smaller ones?
It depends on criticality. A single set simplifies maintenance and footprint; two units give N+1 redundancy but double the capital cost and the service plan.
More from the range
Full Doosan range: Doosan diesel generator sets · all series and ratings · generator set catalogue · request a quote.
Similar power ratings
- BC-H210D-60 — 210 kVA
- BC-H206D-60 — 206 kVA
- BC-H150D-60 — 150 kVA
- BC-H345D-60 — 345 kVA
Specifications
| Characteristics | |
|---|---|
| Brand | DOOSAN |
| Engine Model | P086TI |
| Voltage (V) | 110/208V 127/220V 230/400V 254/440V 277/480V |
| Power (kW) | 193 |
| Emission Standards | T 2 |
| Phases | Three-phase four-wire system |
| Generator Set | |
|---|---|
| Generator set model | BC-H241D-60 |
| Generator set series | Diesel series |
| Generator set structure type | Open type |
| Others | |
|---|---|
| Rating (kVA) | 241 |