Diesel generator set - DOOSAN BC-H1018D-60 (814 kW / 1018 kVA)
BOCHI POWER Doosan gensets use Doosan SP and DP family engines with a robust architecture and low specific fuel consumption. Integrated and tested by BOCHI POWER.
| Model | BC-H1018D-60 |
| Standby power | 1018 kVA / 814 kW |
| Prime power | 925 kVA / 740 kW |
| Engine | DP222CB-2 |
| Frequency | 60 Hz |
| Voltage | Multi-voltage 110/208 - 277/480 V |
| Phases | Three-phase, four-wire |
| Dimensions (mm) | 3700 x 1700 x 2200 |
| Type | Open set |
Built, integrated and tested by BOCHI POWER.
Overview
The Diesel Generator Set - DOOSAN BC-H1018D-60 (814 kW / 1018 kVA) is a 1018 kVA / 814 kW standby diesel generator set, built around a DP222CB-2 engine and open type configuration. It delivers 60 Hz, three-phase four-wire, at 110/208 V – 277/480 V.
Backup power for heavy industry and projects: continuous-process plants, mining and infrastructure, where the set usually comes with synchronising gear, an external tank and a maintenance plan set by running hours. BCP’s Doosan range spans 8 to 1100 kVA with Doosan power, intended for standby duty and for extended running depending on how the fuel and cooling system is specified.
Typical applications
- Mining and heavy industry
- Continuous-process plants
- Data centres and hospitals
- Ports and desalination plants
- Turnkey EPC projects
Standby and prime ratings
The standby rating (1018 kVA / 814 kW) is what the set delivers during a grid outage, for a limited number of hours a year and without sustained overload. The prime rating (PRP) allows continuous duty with varying load. Sizing starts from the real load in kW, corrected by power factor, with headroom left for motor starting.
Frequently asked questions
What is the difference between standby and prime?
Standby is the power available in an emergency, limited to a set number of hours a year; prime is what the set can sustain continuously with varying load. A set sized for standby should not be used as prime generation without re-checking the duty.
What voltage and connection does the BC-H1018D-60 deliver?
It is offered at 110/208 V – 277/480 V, three-phase four-wire, 60 Hz. Final nameplate voltage is fixed at order stage according to the site network and the transfer arrangement.
What maintenance does a set of this size need?
Oil and filter changes every 250–500 h per the engine manual, quarterly oil analysis, injector checks and a load test each quarter. Under prime duty the interval shortens.
More from the range
Full Doosan range: Doosan diesel generator sets · all series and ratings · generator set catalogue · request a quote.
Similar power ratings
- BC-H1100D-60 — 1100 kVA
- BC-H935D-60 — 935 kVA
- BC-H880D-60 — 880 kVA
- BC-H825D-60 — 825 kVA
Specifications
| Characteristics | |
|---|---|
| Brand | DOOSAN |
| Engine Model | DP222CB-2 |
| Voltage (V) | 110/208V 127/220V 230/400V 254/440V 277/480V |
| Power (kW) | 814 |
| Emission Standards | T 2 |
| Phases | Three-phase four-wire system |
| Generator Set | |
|---|---|
| Generator set model | BC-H1018D-60 |
| Generator set series | Diesel series |
| Generator set structure type | Open type |
| Others | |
|---|---|
| Rating (kVA) | 1018 |