Skip to Content

Diesel generator set - PERKINS BC-P1250D-50 (1000 kW / 1250 kVA)

https://www.nanwan.cc/web/image/product.template/16126/image_1920?unique=c045af4
(0 review)

BOCHI POWER Perkins gensets carry Perkins 400, 1100, 1300, 2000 and 4000 series engines, known for transient load capability and easy maintenance. The set is integrated and factory tested by BOCHI POWER.

ModelBC-P1250D-50
Standby power1250 kVA / 1000 kW
Prime power1125 kVA / 900 kW
Engine4008-30TAG3
Frequency50 Hz
VoltageMulti-voltage 110/208 - 277/480 V
PhasesThree-phase, four-wire
Dimensions (mm)4735 x 2261 x 2256
TypeOpen set

Built, integrated and tested by BOCHI POWER.

$ 0.00 Tax Excluded

0.00 Bs Tax Excluded

Not Available For Sale

  • Brand
  • Engine Model
  • Voltage (V)
  • Power (kW)
  • Emission Standards
  • Phases
  • Generator set model
  • Generator set series
  • Generator set structure type
  • Rating (kVA)

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Overview

Rated Diesel Generator Set - PERKINS BC-P1250D-50 (1000 kW / 1250 kVA) standby, the BC-P1250D-50 comes built around a 4008-30TAG3 engine, in open type configuration, and delivers 50 Hz, three-phase four-wire, at 110/208 V – 277/480 V.

Backup power for heavy industry and projects: continuous-process plants, mining and infrastructure, where the set usually comes with synchronising gear, an external tank and a maintenance plan set by running hours. BCP’s Perkins range spans 10 to 2500 kVA with Perkins power, intended for standby duty and for extended running depending on how the fuel and cooling system is specified.

Typical applications

  • Mining and heavy industry
  • Continuous-process plants
  • Data centres and hospitals
  • Ports and desalination plants
  • Turnkey EPC projects

Standby and prime ratings

The standby rating (1250 kVA / 1000 kW) is what the set delivers during a grid outage, for a limited number of hours a year and without sustained overload. The prime rating (PRP) allows continuous duty with varying load. Sizing starts from the real load in kW, corrected by power factor, with headroom left for motor starting.

Frequently asked questions

What is the difference between standby and prime?

Standby is the power available in an emergency, limited to a set number of hours a year; prime is what the set can sustain continuously with varying load. A set sized for standby should not be used as prime generation without re-checking the duty.

What voltage and connection does the BC-P1250D-50 deliver?

It is offered at 110/208 V – 277/480 V, three-phase four-wire, 50 Hz. Final nameplate voltage is fixed at order stage according to the site network and the transfer arrangement.

What maintenance does a set of this size need?

Oil and filter changes every 250–500 h per the engine manual, quarterly oil analysis, injector checks and a load test each quarter. Under prime duty the interval shortens.

More from the range

Full Perkins range: Perkins diesel generator sets · all series and ratings · generator set catalogue · request a quote.

Similar power ratings

Specifications

Characteristics
Brand PERKINS
Engine Model 4008-30TAG3
Voltage (V) 110/208V 127/220V 230/400V 254/440V 277/480V
Power (kW) 1000
Emission Standards T 2
Phases Three-phase four-wire system
Generator Set
Generator set model BC-P1250D-50
Generator set series Diesel series
Generator set structure type Open type
Others
Rating (kVA) 1250